Table 1 Maximum elemental U-value (taken from Technical Guidance Document Part L 2011)
Where the source of space heating is underfloor heating, then a U-value of 0.15W/m2K should be satisfactory (Section 1.3.2.2 from Part L 2011). From a thermal bridge viewpoint, Part L recommends referring to the Acceptable Construction Details and the guidance on limiting thermal bridging and air infiltration provided by the Department of the Environment, Community and Local Government. A number of companies have developed some innovative solutions to providing a foundation with little or no thermal bridging, good air-tightness and good overall energy performance. Viking House and KORE have developed the passive slab which can deliver a U-value of 0.08W/m2K. Passive House Builders have developed their own solution (click into foundation to see detail) which has been successfully used on certified passive houses both in Athenry and Oranmore in County Galway. Aeroboard also provide the Supergrund system for passive house construction.
We will have a look at these systems as well as a few others on offer this week in class.